Description
Extend AutomationMB25 Grain Halogen Moisture Analyzer 0.005g Readability 110g Capacity
Speed, Simplicity and Affordability
The new OHAUS MB23 and MB25 Basic Moisture Analyzers combine high quality and durable construction
into a sleek, compact design. The MB23 and MB25 offer dependable, accurate, results for a wide
variety of applications.
Standard Features Include:
Flexible Performance –
The OHAUS MB23 and MB25 provide accurate results at either 0.1% or
0.05% readability. And with your choice of infrared or halogen heating, they are ideal for textiles,
wastewater, ceramics, food and other applications that require IR heating elements and
measurements to 0.1% or 0.05%.
Simple to Operate –
Set up and operation is extremely easy. Just press and hold the temperature
or time buttons to set drying parameters, add your sample and begin the test process. This makes
the MB23 and MB25 ideal for routine tasks performed by operators of all skill levels.
Compact, Easy-to-Clean Design –
The compact footprint (17 x 13 x 28 cm) of the OHAUS MB23
and MB25 is designed to take up less space. Their easy-to-clean heating chamber is ideal for
frequent use and inexpensive maintenance.
OVERVIEW
1.
The MB25 provides precise moisture content determination at an unbeatable value. With a large backlit LCD display, standard RS232 port, 110g capacity with a readability of 0.005g/0.05% and halogen heating, the MB25 offers moisture analysis for any budget.
Applications:
Percent Moisture Determination, Percent Solid Determination, Weighing
Display:
Backlit liquid crystal display (LCD)
Operation:
Power cord (included)
Communication:
RS232 (included)
Construction:
Halogen heat source, ABS housing, metal pan support, metal pan handler, in-use cover
Design Features
3 shut off criteria (manual, timed or auto), 1 standard heating profile, 50° to 160° C heating range (5° C increments)
2.
MB25's halogen heating element quickly dries samples, and saves the operator ample time in comparison to moisture analysis procedures using a traditional oven.
3.
With a bright backlit LCD and easy one-button setup and menu navigation, MB25 is extremely user-friendly.
4
.MB25 is very easy-to-clean to ensure the integrity of your samples and its compact design allows it to fit seamlessly into most workspaces.
1. INTRODUCTION
Safety Precautions
For safe and dependable operation of this moisture Analyzer, please comply with the following safety
precautions:
1.Use the Analyzer exclusively for determination of moisture in samples. Improper operation of the Analyzer
can endanger personnel and cause property damage.
2.If the Analyzer is used in a manner not specified in this manual, the protection provided may be impaired.
3.Verify that the input voltage printed on the voltage identification label information and the plug type matches
the local AC power supply.
4.The Analyzer has a 3-pin power cable that includes a ground connection. Intentionally disabling the
equipment grounding connection is prohibited.
5.Do not position the Analyzer so that it is difficult to disconnect the Power Plug from the local AC power supply.
6.Make sure that the power cord does not pose any obstacle or tripping hazard.
7.Do not operate the Analyzer in hazardous, wet or unstable environments.
8.Disconnect the Analyzer from the power supply when cleaning the Analyzer.
9.Ensure sufficient free space around the Analyzer as a safety zone. Allow at least 1 meter of free space above
the Analyzer.
10.The Analyzer must be operated only by trained personnel who are familiar with the properties of the samples
being tested and with the equipment operation.
11.Use appropriate personal safety equipment such as safety glasses, gloves, protective clothing and
respirators.
12.Do not make any modifications to the Analyzer.
13.Service should be performed only by authorized personnel.
The Moisture Analyzer works with heat!
1..Never place flammable materials on, below or next to the Analyzer.
2..Use caution when removing a test sample. The sample, the sample chamber, the heating element and the
surrounding areas may be very hot and can cause burns.
Some samples require special care!
1.Should there be any uncertainty regarding the safety of a substance, perform a careful risk analysis. In such
cases, never leave the Analyzer unattended.
2.
Fire or explosion:
Substances which contain solvents or release flammable or explosive vapors when
heated. With such samples, work at drying temperatures low enough to prevent the formation of flames or
an explosion.
2.
Poisoning or burning:
Substances which contain toxic or caustic components should only be dried in a fume
hood.
3.
Corrosive:
Substances which release corrosive vapors when heated should be tested in small amounts.
4.The user assumes responsibility for any damage caused by the use of these types of samples.
2. INSTALLATION
Package Contents
Moisture Analyzer
Draft Shield
In-Use Cover
Pan Support
Power Cable
50 Sample Pans
Glass Fiber Pad
Instruction Manual
Sample Pan Handler (MB25 only)
Selecting the Location
1.Operate the Analyzer on a firm, level surface.
2. Select a location that is safe and with adequate ventilation. Fire, corrosive or toxic fumes and other hazards associated with
the test samples will require specially prepared locations.
3.Ensure that the location has easy access to the local AC power supply.
4.Avoid locations with rapid temperature changes, excessive humidity, air currents, vibrations, electromagnetic fields, heat
or direct sunlight.
3. MAINTENANCE
Weight Calibration
Weight calibration is rarely required. Moisture analyzers use relative weight values to determine the results, so a minor offset
from the absolute weight has little effect on accuracy. OHAUS moisture analyzers have rugged, high quality temperature
stabilized weighing modules that retain their calibration over long periods of time.
(1) Remove any load on the Pan Support including the sample pan.
(2) Press and hold Cal while in the Weigh mode. “CAL” will appear followed by “50.00g”.
(3) Place a 50g calibration mass on the Pan Support. The display will show “-----”.
(4) Remove the mass when “--0--” is shown on the display. The display will show “-----”.
(5) The Analyzer will return to Weigh mode when calibration is complete.
Note: Pressing START will cancel the calibration without saving the changes.
Specifications
Model
MB23
MB25
Capacity
110g
Repeatability (Std Dev) (g)
0.3% (3g sample)
0.2% (10g sample)
0.2% (3g sample)
0.05% (10g sample)
Readability
0.1% / 0.01g
0.05% / 0.005g
Sample Size
3g to 20g typical, 0.5g min.
Interface
Bidirectional RS-232
Timer
1 - 99 minutes, 30-second increments to 60 minutes
Heating Technology
Infrared (no glass)
Halogen
Temperature Range
50°C to 160°C in 5° increments
Power
100 to 240 VAC, 50/60 Hz
Tare Range
To capacity by subtraction
Operating Temperature Range
5° to 40°C
Display Type
Custom backlit LCD
Displays
% moisture or % solids or weight (g), temperature, time
Pan Size (Diameter)
90 mm
Dimensions (W x H x D)
17 x 13 x 28 cm
Weight
5 kg
Included Accessories
Sample Pans (Quantity 50)
Standard
In Use Cover
Standard
Sample Pan Handler
Optional (PN 11113873)
Standard
Notice: Because,the international air shipping forbid to ship liquid,powder and batteries, If you purchased goods containing such items, we will not be putting them packing. Thank you for your support.
Payment:
Payment must be made within 12 days after the auction/bid ends, or eBay will open Unpaid Item case automatically later.
Feedback:
We strive for positive Feedback on all transactions and nothing less than an overall Detail Seller Rating (DSR) of 5 STAR.If you are considering giving a neutral or negative Feedback or a low DSR. Do write to us and give us an opportunity to address your concerns firstly.We will leave the positive feedback when we got your positive feedback.
Delivery details:
We are not responsible for undeliverable address. We reserve the right to charge the shipping fee again for returned items due to wrong address.
Items are generally shipped within 10 business day after your payment has been cleared (Sat. & Sun. excluded.)
RETURN POLICY:
We offer 14 days return policy from the day you received your item under the following conditions All returns must be in the original non-damaged condition, including packaging, documentation, warranty cards, manuals and accessories or else it will not be accepted.
Original shipping & handling charges are not refundable.
Customer is responsible for shipping, shipping cost and proof of delivery on all returns. Please be sure that you return shipments are properly packed and fully insured. We are not responsible for returned packages if lost by shipper/carrier or got damaged buy carrier.
Shipping cost (to and from buyer) will be charged for any refused shipping delivery (include duties, taxes and customs fee if any).
TAX&VAT
Please read this before buying International Shipping may Be Delayed Due to Customs. Customers are Responsible For All Import Charges, Tariffs, Duties, Taxes, and Fees Associated with Import of the product. Shipping Charges does not include any Import Charges, Tariffs, Duties, Taxes, and Fees Associated with it.
Contact us:
Please contact us with any comments, questions or suggestions that you may have bysending ebay message, All the mail will be replied within 24 hours. Please ensure your mail box would not blocked / filtered our mails.we will be happy to assist you. please feel free to contact us for WHOLESALES deal,we will surely give you a satisfatory price. We would try our best to serve you with any question / problem. Please contact us first before leaving Negative / Neutral Feedback or open any cases.
Copyright 2018 Extend Automation. All rights reserved.